Thermal Map smartRack Sensors - KVMGalore® | Tech Solutions Made Easy™
Thermal Map smartRack Sensors

Thermal Map smartRack Sensors

A complete rack monitoring system with top, middle and bottom cabinet thermal and humidity maps, and front-to-back thermal and pressure differentials
Read more below...

Air Pressure Differential Sensor

1) Air Pressure Differential Sensor Model No. DAPS Ships within two weeks or less

FREE GROUND SHIPPING!


$193.19 MSRP: $210.00 - You save $16.81
Cabinet Analysis Sensor

2) Cabinet Analysis Sensor Model No. CAS Ships within two weeks or less

FREE GROUND SHIPPING!


$363.00 MSRP: $395.00 - You save $32.00
Cabinet Monitoring Bundle

3) Cabinet Monitoring Bundle Model No. CMB In stock

FREE GROUND SHIPPING!


$312.00 MSRP: $340.00 - You save $28.00
Cabinet Temperature and Humidity Map Sensor

4) Cabinet Temperature and Humidity Map Sensor Model No. CTHMS-V2 In stock

FREE GROUND SHIPPING!


$209.00 MSRP: $230.00 - You save $21.00
Temperature and Humidity Map Sensor

5) Temperature and Humidity Map Sensor Model No. THMS-V2 In stock

FREE GROUND SHIPPING!


$174.79 MSRP: $190.00 - You save $15.21

A complete rack monitoring system 

top, middle and bottom cabinet thermal and humidity maps, and front-to-back thermal and pressure differential, for detecting hot-spots and cold-spots 


AKCP Thermal MapThermal map sensors help identify and eliminate hots-pots in your cabinets by identifying areas where temperature differential between front and rear are too high.

Thermal maps consist of a string of 3x temperature sensors and 1x humidity sensor. They are placed at the top, middle and bottom of the rack.

Two strings can be combined on a single sensor port, to be placed in the front and rear of the cabinet. This configuration of sensors monitors the air intake and exhaust temperatures of your cabinet, as well as the ∆T of the rack.

Use thermal map sensors to identify cabinet hot spots that can endanger your uptime.

Thermal map sensors also identify cold-spots in your data center. Eliminating cold spots frees stranded capacity and saves energy.

Are there areas of your data center that are over cooled? Over cooling wastes energy. Identifying and eliminating cold spots can increase data center energy efficiency and lower operational costs. It also means you can release stranded capacity - increasing server loads in cold spots allows increased compute power without any increase in cooling capacity.

Thermal map sensors connect to AKCP sensorProbe+ base units. Extendable up to a maximum of 15 meters cable length, you can monitor multiple cabinets from a single IP address. Up to 16 thermal maps can be connected to a single SPX+, or deploy the SP1+ on each rack.

The included sensor splitter box (i2C Splitter) allows 2 strings to be connected to a single sensor port, and combined with the contactless current meter to give thermal mapping and power monitoring for each rack. This is required for AKCP sensorCFD™ calcualtions.

Air Pressure Differential Sensor: Differential pressure sensor that checks for pressure differential between front and back of a cabinet

Cabinet Analysis Sensor: Two strings of pre-wired 3x temperature and 1x humidity sensors for monitoring top middle and bottom temperature values in the front and back of a cabinet + a differential pressure sensor that checks for pressure differential between front and back of a cabinet, all easily installed into one sensorProb+ sensor port

Cabinet Temperature and Humidity Map Sensor: Two strings of pre-wired 3x temperature and 1x humidity sensors for monitoring top middle and bottom temperature values in the front and back of a cabinet, and easy installation into one sensorProb+ sensor port

Temperature and Humidity Map Sensor: A string of pre-wired 3x temperature and 1x humidity sensors for monitoring top middle and bottom temperature values, and easy installation into one sensorProb+ sensor port

Comparing