Network-Switched PDUs
PDUs w/ networked access provide individual outlet-level control to switch outlets on/off for remote equipment rebooting; remote & local power consumption (high-res color LCD) monitoring
Read more below...
1) Network-Switched PDU, 1U, 15A, 120V, (8) 5-20R, 5-15P Cord Model No. LP-61110 Ships within 3-4 business days or less
2) Network-Switched PDU, 1U, 20A, 120V, (8) 5-20R, L5-20P Cord Model No. LP-61210 Ships within 3-4 business days or less
3) Network-Switched PDU, Zero-U, 15A, 120V, (8) 5-20R, 5-15P Cord Model No. LP-61100 Ships within 3-4 business days or less
4) Network-Switched PDU, Zero-U, 20A, 120V, (24) 5-20R, L5-20P Cord Model No. LP-61200 Ships within 3-4 business days or less
5) Network-Switched PDU, Zero-U, 20A, 208V, (21) C13 & (3) C19, L6-20P Cord Model No. LP-62201 Ships within 3-4 business days or less
6) Network-Switched PDU, Zero-U, 30A, 120V, (24) 5-20R, L5-30P Cord Model No. LP-61300 Ships within 3-4 business days or less
7) Network-Switched PDU, Zero-U, 30A, 208V, (21) C13 & (3) C19, L6-30P Cord Model No. LP-62300 Ships within 3-4 business days or less
Legrand network-switched PDUs with load monitoring, individual outlet cycling and notification thresholds
provide remote power-consumption monitoring and outlet-level control
• Networked Controller: Enables remote and local monitoring of the PDU and peripherals
• Circuit Breaker Trip Detection / Alerting: Get notification instantly in the instance of a tripped circuit breaker
• Delayed Power Sequencing: Sequence the order in which each outlet is turned on or off to avoid dropped power loads or circuit overloading
• Outlet Use Management: From the PDU GUI, you can remotely identify named outlets and if an outlet is on or off
• Advanced Load Monitoring: View and control the power being drawn for the entire PDU, receive notifications of potential issues or when near max amperage draw
• User Defined Notifications: User defined thresholds for power draw or environmental factors with notifications if thresholds have been met
• High-Resolution Color LCD: Displays energy reading, current, and voltage; important configuration settings, alarm settings, and control outlets which simplifies commissioning
• Integrated Locking Outlets on IEC Receptacles: Eliminates the need for special power cords that lock at the PDU
• Rotatable Cord: Enables maximum flexibility for routing the input plug - simplifying the installation of Zero U PDUs
• Mounting Types: Available in horizontal and vertical (on rail, flush rail, and button mount) configurations to ensure power distribution is optimally located and simple to install
• PDU Linking: Cascade up to 16 PDUs via Ethernet or USB—this can minimize port usage on network switches or consolidate accessibility to multiple PDUs from a single IP address
• Hydraulic-Magnetic Breakers: Provide less heat dependent local protection and quick recovery from circuit overload, by utilizing a two-step response curve—these breakers provide a delay on normal overcurrents, while tripping quickly on short circuits
• Optional Environmental Sensors: Can alert of any threats of downtime or potential physical security breaches
• Software Interoperability: Seamlessly integrate into any monitoring software with open JSON-RPC interface
• Software Compatibility: SNMP, LUA, Java, JavaScript, and Perl
• Warranty: 2 years
Legrand network-switched PDUs distribute voltage and current to power IT equipment in a rack and cabinet. They also manage and control power to connected equipment, enabling load monitoring, individual outlet power cycling, and power sequencing.
Network-switched PDUs enable authorized users to securely power-cycle outlets remotely. They minimize inrush currents through power sequencing, prevent unauthorized device provisioning, power off devices that are not in use to conserve energy, and reboot devices to quickly restore services.
Network-switched PDUs also meter power at the PDU inlet-level. They display the inlet power data both locally and over a network. They also allow for sensors to be connected and monitored through the PDU interface.
This control can be accessed locally or remotely, multiplying the reach and ability of IT staff and caretakers.
A single portal view provides visibility and control of power usage and available capacity, which simplifies the maintenance responsibilities of taxed IT departments.
Legrand network-switched PDUs enable line level power metering in real time, allowing remote monitoring of the load level, custom notifications, and user specified conditions.
The PDUs provide visibility and reporting of power usage on the PDU's color LCD screen and to tablets, smart phones, or computers from nearly anywhere.
Cord Locking System
The security of cable connections is a critical element which must be considered to ensure longevity of the installation. IEC receptacles have a cord locking system which prevents accidental disconnection due to human error or vibration.
Networked PDU Controller - The Heart of the Networked PDUs
The Legrand® PDU controller allows local and remote access to all critical measurement data. The bright color LCD display will change color according to the alert level detected by the iPDUs; your field technicians can quickly identify iPDUs on which the thresholds have been exceeded, obtain correct power supply data immediately, and take appropriate action.
Directly Accessible Data
Directly accessible data makes it easier to view the data center power supply data and information about the environment. The responsive web user-interface can be accessed from any device or tablet, or directly from a desktop computer.
The overview screen provides the most important information at a glance, so you can easily monitor your PDU health and critical data, and also view the cabinet energy consumption in real time.
A Wide Bright LCD Display with Adaptive Color Screen
The LCD display on the unit changes color according to the alert level, making it easier for the technical teams to see the critical information.
Cable Orientation
A rotatable inlet cord allows for flexibility in design, installation, and configuration of your setup. Legrand zero-U PDU features a 330° rotatable cable entry for perfect cable orientation and no interference in the cabinet.
Magnetic-Hydraulic Circuit Breaker
This Legrand PDU features a rugged circuit breaker with delayed tripping curve, which provides the maximum flexibility and safety of people and equipment. The circuit breaker is monitored by the embedded firmware and issues configurable alerts in the event of an overload or unwanted tripping.