NI30209L: Unit-level monitored PDU, 30A, 230/400V 3-phase WYE, rack-mount, 6x rear locking IEC C19 receptacles 

environmental compatible, 10-foot cord with 3P+N+E (IP44) plug, black powder coat finish 


• Input power monitoring
• Environmental monitoring via optional remote sensors
• Daisy-chain Ethernet connectivity
• Local high-visibility LED display
• Visible Light Communication (VLC) technology
• Upgradeable by replacing the interchangeable monitoring device (IMD) module

Geist's NI30209L unit-level monitored PDU provides real-time power metrics to help prevent overloads and safely optimize load levels.

The unit offers local and IP-based monitoring with quick access to real-time power metrics and optional environmental sensor data.

IMDUsing Visible Light Communication (VLC) technology, NI30209L optically transmits power usage data from its LED display to a handheld device over the Geist Mobile App, presenting comprehensive real-time power usage data down to the phase and circuit levels.

Geist's rack power distribution unit (rPDU) gives data-center managers the flexibility to install the intelligence required today with the option to upgrade technology as needs evolve. To establish this upgrade path, Geist incorporated an interchangeable monitoring device (IMD) module into its rPDU design.

rPDUs last for many years and with the IMD design, businesses are able to upgrade their rPDUs to newer monitoring technologies in the future without having to replace the entire rPDU. With the Geist Upgradeable hot-swap technology, users may easily upgrade PDUs to the latest available technology by replacing the interchangeable monitoring device (IMD) module, all without causing any interruption in power delivery.

Plug Receptacles
3P+N+E IEC C19
3P+N+E Splashproof (IP44) plug 6x rear locking IEC C19


• Horizontal, 19" rack-mount form factor, 1U
• Volts: 230/400V WYE
• Amps: 30A
• kW-input: 16.6kW
• Cord length: 10 feet
• Circuit breaker: Yes
• On/off switch: Yes

Aggregate - Total Unit Monitoring
• Kilowatt/Hour (kWh)
• Watts (W)
• Apparent Power (VA: Volt-Ampere)
• Power Factor (PF)
• Power Measurements: Compliant with ANSI C12.1 and IEC 62053-21 at 1% accuracy class requirements

Phase (A, B, C) Monitoring
• Kilowatt/Hour (kWh)
• Watts (W)
• Apparent Power (VA: Volt-Ampere)
• Power Factor (PF)
• Voltage (V)
• Amps (A)
• Power Measurements: Compliant with ANSI C12.1 and IEC 62053-21 at 1% accuracy class requirements

Circuit / Breaker Monitoring 
• Amps (A)
• Circuit/Breaker Current Measurements Independently Tested and Verified at 2% Accuracy

Optional Environmental Sensors
• Compatible digital (w/ RJ connector) and analog (dry-contact) sensors and probes
• Analog (dry-contact) sensors require the use of an analog to digital converter