VP8868: Unit-level monitored PDU, 35A, 208V, 3-phase DELTA, zero-U, 36x IEC C13 and 6x IEC C19 receptacles 

environmental compatible, breakered w/ on/off switch, 10-foot cord with twist-lock 3P+E CA plug, black powder coat finish 


• Input power monitoring
• Environmental monitoring via optional remote sensors
• Daisy-chain Ethernet connectivity
• Local high-visibility LED display
• Visible Light Communication (VLC) technology
• Upgradeable by replacing the interchangeable monitoring device (IMD) module

Geist's VP8868 unit-level monitored PDU provides real-time power metrics to help prevent overloads and safely optimize load levels.

The unit offers local and IP-based monitoring with quick access to real-time power metrics and optional environmental sensor data.

IMD

Using Visible Light Communication (VLC) technology, VP8868 optically transmits power usage data from its LED display to a handheld device over the Geist Mobile App, presenting comprehensive real-time power usage data down to the phase and circuit levels.

Geist's rack power distribution unit (rPDU) gives data-center managers the flexibility to install the intelligence required today with the option to upgrade technology as needs evolve. To establish this upgrade path, Geist incorporated an interchangeable monitoring device (IMD) module into its rPDU design.

rPDUs last for many years and with the IMD design, businesses are able to upgrade their rPDUs to newer monitoring technologies in the future without having to replace the entire rPDU. With the Geist Upgradeable hot-swap technology, users may easily upgrade PDUs to the latest available technology by replacing the interchangeable monitoring device (IMD) module, all without causing any interruption in power delivery.

Plug Receptacles
3P+E CA IEC C13  IEC C19
Twist-lock 3P+E CA 36x IEC C13 and 6x IEC C19


• Vertical, 72 inches
• Volts: 208V
• Amps: 35A
• kW-input: 10.0kW
• Cord length: 10 feet
• Circuit breaker: Yes
• On/off switch: Yes

Aggregate - Total Unit Monitoring
• Kilowatt/Hour (kWh)
• Watts (W)
• Apparent Power (VA: Volt-Ampere)
• Power Factor (PF)
• Power Measurements: Compliant with ANSI C12.1 and IEC 62053-21 at 1% accuracy class requirements

Phase (A, B, C) Monitoring
• Kilowatt/Hour (kWh)
• Watts (W)
• Apparent Power (VA: Volt-Ampere)
• Power Factor (PF)
• Voltage (V)
• Amps (A)
• Power Measurements: Compliant with ANSI C12.1 and IEC 62053-21 at 1% accuracy class requirements

Circuit / Breaker Monitoring 
• Amps (A)
• Circuit/Breaker Current Measurements Independently Tested and Verified at 2% Accuracy

Optional Environmental Sensors
• Compatible digital (w/ RJ connector) and analog (dry-contact) sensors and probes
• Analog (dry-contact) sensors require the use of an analog to digital converter