MNU3EDR1-12P938-3TL21A0E10-S

Model No. NU30078L Ships within 7 business days or less

MNU3EDR1-12P938-3TL21A0E10-S
Buy this item and earn 1,304 ClubPoints.

NU30078L: Switched, outlet-level metered PDU, 30A, 120/208V 3-phase WYE, rack-mount, 9x rear locking IEC C13 and 3x rear locking IEC C19 receptacles 

environmental compatible, breakered w/ on/off switch, 10-foot cord with NEMA twist-lock L21-30P plug, black powder coat finish 


• Remote outlet switching
• Input power monitoring
• Environmental monitoring via optional remote sensors
• Daisy-chain Ethernet connectivity
• Local high-visibility LED display
• Visible Light Communication (VLC) technology
• Upgradeable by replacing the interchangeable monitoring device (IMD) module

Geist's NU30078L switched, unit-level monitored PDU provides reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of input power usage via remote network access.

The unit makes it possible to remotely reboot outlets to power cycle unresponsive IT equipment or increase runtime of critical equipment upon power failure with outlet-level control.

The unit offers local and IP-based power monitoring options for quick access to critical power usage information to evaluate energy usage trends and maximize uptime.

Environmental monitoring capabilities with the addition of optional environmental sensors ensure users have critical infrastructure data at their fingertips to prevent climate-related equipment failure and system downtime.

Fault-tolerant daisy chaining with RSTP simplifies intelligent rPDU connectivity and ensures data is reported even when a break in the network chain occurs. Supports up to 40 rPDUs.

IMD

Using Visible Light Communication (VLC) technology, NU30078L optically transmits power usage data from its LED display to a handheld device over the Geist Mobile App, presenting comprehensive real-time power usage data down to the phase and circuit levels.

Geist's rack power distribution unit (rPDU) gives data-center managers the flexibility to install the intelligence required today with the option to upgrade technology as needs evolve. To establish this upgrade path, Geist incorporated an interchangeable monitoring device (IMD) module into its rPDU design.

rPDUs last for many years and with the IMD design, businesses are able to upgrade their rPDUs to newer monitoring technologies in the future without having to replace the entire rPDU. With the Geist Upgradeable hot-swap technology, users may easily upgrade PDUs to the latest available technology by replacing the interchangeable monitoring device (IMD) module, all without causing any interruption in power delivery. 

Plug Receptacles
 L21-30P IEC C13  IEC C19
NEMA twist-lock L21-30P 9x rear locking IEC C13 + 3x rear locking IEC C19


• Horizontal, 19" rack-mount form factor, 3U
• Volts: 120/208V
• Amps: 30A
• kW-input: 8.6kW
• Cord length: 10 feet
• Circuit breaker: Yes
• On/off switch: Yes

Input Monitoring
• Kilowatt/Hour (kWh)
• Watts (W)
• Apparent Power (VA: Volt-Ampere)
• Power Factor (PF)
• Voltage (V)
• Amps (A)
• Power Measurements: Compliant with ANSI C12.1 and IEC 62053-21 at 1% accuracy class requirements

Phase (A, B, C) Monitoring
• Kilowatt/Hour (kWh)
• Watts (W)
• Apparent Power (VA: Volt-Ampere)
• Power Factor (PF)
• Voltage (V)
• Amps (A)
• Power Measurements: Compliant with ANSI C12.1 and IEC 62053-21 at 1% accuracy class requirements

Circuit / Breaker Monitoring 
• Amps (A)
• Circuit/Breaker Current Measurements Independently Tested and Verified at 2% Accuracy

Outlet Monitoring
• Kilowatt/Hour (kWh)
• Watts (W)
• Apparent Power (VA: Volt-Ampere)
• Power Factor (PF)
• Voltage (V)
• Amps (A)
• Power Measurements: Compliant with ANSI C12.1 and IEC 62053-21 at 1% Accuracy Class Requirements.

Remote Power Management
Individual outlet switching with optional use-defined time delays and sequential power-up

Optional Environmental Sensors
• Compatible digital (w/ RJ connector) and analog (dry-contact) sensors and probes
• Analog (dry-contact) sensors require the use of an analog to digital converter